Air Source Heat Pump

Item No.: 13
Air source heat pump is a kind of use can make heat from low heat source high air flow to the high heat source energy saving device. It is a form of heat pump. As the name suggests, the heat pump is like a pump.
Description Technical data Related Products
Air source heat pump can directly replace traditional coal-fired, oil-fired and electric boilers, and directly connect the end equipment such as floor radiant heating system, fan coil unit, radiator, heat preservation water tank, etc.
It is used for heating rooms in winter, cooling in summer and supplying domestic hot water throughout the year in cold areas.
 
1.Advanced technology
 
(1)The invention has wide application range, and can stably cool and heat at the outdoor temperature of -26 to 24 deg C ..
 
(2)Ultra-low temperature heating. The low-temperature air source heat pump unit adopts a special compressor for the heat pump, thus realizing quasi-two-dimensional compression during heating operation, greatly improving the low-temperature heating capacity and energy efficiency ratio, and realizing safe heating operation at-26 DEG C; The lower the temperature, the better the heating effect. Take the 75KW model as an example.
 
(3)Jet-enhanced enthalpy compressor+super-cooling injection technology, greatly improve low-temperature heating capacity
 
2.Leading operation control technology
(1)Unit rotation operation technology. According to the usage load of the system, the heat pump units with priority on are set in rotation, and the operation time of each unit is evenly distributed, thus greatly improving the reliability and service life of the unit. According to frosting conditions, the unit rotates to melt frost to realize uninterrupted heating.
 
(2)Intelligent defrosting technology to reduce heating attenuation. Heat pump units are prone to frost under the conditions of low ambient temperature and high humidity. Yuexin low-temperature air source heat pump unit can accurately judge the defrosting timing according to the main parameters and load changes of heating operation, achieve quick defrosting with frost and normal heating without frost, and can perform forced manual defrosting according to actual conditions.
 
3.Multiple protection functions to ensure safe operation of the system
The modular structure is adopted, and the units are started in stages to reduce the impact of the starting current of the units on the power grid. The unit is equipped with high and low voltage switch, anti-freezing protection device, flow controller, overload protection device, power supply phase sequence protection device, etc., and is equipped with operation control device. In case of failure, the controller will give real-time automatic alarm.
 
 
 
4.Advanced intelligent control system. A single controller can realize centralized control of up to 16 heat pump units, manage the start-stop sequence of the units, and users can know the running status and fault status of the units in time through the controller.
 
5.Environmentally friendly refrigerant, low carbon and energy saving.



 
Model YXRB-KFRS-52D YXRB-KFRS-78D
Cooling capacity kw 130 195
Heating capacity kw 140 210
Consumption of total electric power cooling kw 40.2 60.9
heating kw 43.3 65.6
Power supply 380V-3N-50HZ
Water side heat exchanger Water flow m³ 22.4 33.5
Water pressure drop kPa 50-60 50-60
Unit dimensions L mm 2050 2050
W mm 1650 2650
H mm 2260 2230
Noise dB(A) 69 69
Refrigerant   R22 R22
Unit weight kg 1400 2000
Pipe diameter of inlet and outlet pipes   DN65 DN80
 
Model (low temperature air supplement and enthalpy increase) YXRB KFRS-3D KFRS-5D KFRS-6D KFRS-6D KFRS-8D KFRS-10D KFRS-15D KFRS-20D KFRS-25D
Cooling Capacity kw 6.9 10.5 13.8 13.8 18 23 35 49 60
Rated Input Power (cooling) kw 2.76 3.93 5.25 5.25 7.17 9.02 13.94 19.52 23.9
Rated Input Current (cooling) A 12.5 17.9 23.9 10 13.6 17.1 26.5 37.1 45.5
Heating Capacity kw 8.3 13.8 16.5 16.5 22 28 38 60 70
Rated Input Power (heating) kw 2.52 3.8 5.06 5.06 6.85 8.59 11.84 18.69 21.81
Rated Input Current (heating) A 11.4 17.3 23 9.6 13 16.3 22.5 35.5 41.5
Heating Capacity kw 5.6 9 11 11 15.8 21.5 29 44 51
Rated Input Power (heating) kw 2.5 3.7 4.8 4.8 7.18 9.27 12.72 19.05 22.08
Rated Input Current (heating) A 11.4 16.8 21.8 9.1 13.6 17.6 24.2 36.2 42
Power supply V/PH/Hz 220/1/50 220/1/50 220/1/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50
Maximum operating current A 18.8 26.8 35.8 14.9 20.4 25.7 39.8 55.7 68.2
Noise Db(A) 52 54 55 55 56 62 64 68 68
Circulating nozzle inch DN25 DN25 DN25 DN25 DN32 DN40 DN40 DN50 DN50
Water flow m³/h 1.19 1.81 2.37 2.37 3.1 3.96 6.02 8.43 10.32
Working substance type   R410a/R22
Unit size(L*M*H) mm 730/500/1280 1195/470/1270 1195/470/1270 1195/470/1270 1475/730/1060 1345/791/1680 1345/791/1680 2150/1030/2135 2150/1030/2135
Net weight kg 110 150 155 155 240 290 330 715 760