News Center

Selection Steps of Fan Coil Unit

Views : 3802
Author : Sherry
Update time : 2019-09-23 14:22:30

Selection Steps of Fan Coil Unit
 

Make clear the type, specification, tuyere position and other requirements of the unit selected by the fan coil unit.

 

1) When selecting fan coil unit, the design preheating load is matched with the sensible heat load of the unit. In most cases, the coil has enough latent heat capacity to meet the design requirements. If outdoor air is used, trim accordingly.

 

2) Heating: The heating capacity of the unit usually selected according to refrigeration is sufficient, and the heat return quantity is selected according to the same water flow rate, i.e. the inlet water temperature is used to meet the indoor heating load.

 

3) Refrigeration: indoor preheating refrigeration load, indoor total thermal refrigeration load, inlet air temperature, inlet water temperature and air volume.

 

Determine the fan coil unit specifications, water volume, required water temperature, pressure drop and other parameters

 

1) Make clear whether the bearing of the fan motor uses an oil-containing or oil-free shaft pump. If an oil-free shaft pump is selected, oil shall be added regularly according to regulations during use.

 

2) Make clear the left or right outlet direction of the water connection pipe of the selected unit (related to pipe layout, etc.).

 

3) The inlet cold water temperature of fan coil unit shall not be lower than 5℃, otherwise it may cause condensation of the unit; When hot water is supplied in winter, the water temperature is generally not more than 60℃, can reduce scaling ,the alternating effect of cold and heat can reduce the expansion force of the expansion pipe., thus affecting heat transfer.

 

4) Pay attention to the heat preservation measures of effluent to avoid condensation and fouling of indoor buildings during summer use.

 

5) The highest part of the unit coil is provided with a vent valve.

 

The above two items are essential in choosing fan coil units. Users are requested to locate the specifications, forms and related parameters of fan coil units according to their own needs, so as to purchase fan coil units better, faster and more effectively.

 

Related News
Read More >>
Water source rooftop chiller unit part in HAVC Water source rooftop chiller unit part in HAVC
Mar .22.2024
The fan coil unit is a common HVAC system terminal device. It can be used independently or in conjunction with other equipment to provide more efficient cooling and heating services. One such example is the water-source chiller.
The quietness and efficiency of Guqin series Horizontal Ultra-Thin Concealed fan coil units The quietness and efficiency of Guqin series Horizontal Ultra-Thin Concealed fan coil units
Mar .22.2024
The Guqin Series Vertical and Horizontal Ultra-Thin Concealed Fan Coil Unit is a HVAC terminal component product produced by Yesncer, named after the world’s intangible cultural heritage – the Guqin. Not only does it have an exquisite appearance, but its
Ultra-low temperature air source heat pump principle and core technology Ultra-low temperature air source heat pump principle and core technology
Dec .27.2023
The principle of ultra-low temperature heat pump system is as follows.
Fan Coil Unit Selection And Product Advantages Fan Coil Unit Selection And Product Advantages
Dec .07.2023
Fan Coil Unit Selection And Product Advantages