Q: Does the fan coil unit purchased from your manufacturer come with this soft connection?
Answer: No. Hose connections are additional accessories. Our prices are for fan coil units only. Accessories you can also buy locally.
Q: Installation diagram of corrugated stainless steel hose.
Answer: In the picture below, the blue arrows I marked are the water inlet and outlet pipes, and the red arrows are stainless steel corrugated pipes. You can clearly see the installation position between them.
Q: fan coil unit installation, and other accessories?
I am a fan coil unit manufacturer, and I am very familiar with this product. Please take my advice.
Although the installation of accessories does not affect the use of the fan coil unit, it determines the performance and service life of the fan coil unit in the later stage.
Horizontal concealed fan coil concealed fittings
I believe you also want to provide more professional services to your customers.
The working principle of the fan coil unit: using cold water and hot water as the medium, the heat and cold energy are transferred to the room through the fan coil air, so as to improve the indoor air temperature.
I reiterate the working principle of the fan coil unit again, and the reason for this is that I want to emphasize that this is indeed a low energy consumption and high environmental protection investment.
For fan coil unit installation, what else should be paid attention to?
The fan coil unit has left inlet (outlet) water and right inlet (outlet) water, which is to match the water pipe arrangement of your installation environment and facilitates installation.
3. How to judge the left and right ports of the fan coil?
I suggest you do this, it is easier to judge the right and left ports of the fan coil unit.
When judging, you should face the air outlet. If the water inlet and outlet are on the left side, it is the left water inlet, and if it is on the right side, it is the right water inlet. Most of the vertical surface-mounted coils are for the rear outlet (inlet) water.
4. The inlet and outlet water pipes of the fan coil unit: bottom in and top out.
Note:
A. When taking over, too much force will damage the fan coil unit.
B. The inlet and outlet pipes should be insulated, and the threaded connection should be sealed with PTFE raw tape. The drainage pipe should maintain a sufficient slope to facilitate the timely discharge of condensed water.
5. The installation height and position of the fan coil unit should be determined according to the drawings and the height of the civil construction ceiling, so as to avoid the air outlet that cannot be installed downward or sideways.
At the same time, the elevation of the water inlet and outlet pipes and the slope of the condensate water pipes should also be considered. Before installation, it must be matched with the drawings, and professional issues should be considered comprehensively before construction.
If you are a personal family user, then I hope you can ask the local professional fan coil installation engineering team for help;
If you are a dealer or a builder, I hope you can show the professional architectural CAD drawings to the engineering team technicians for a look, and seek his help.