With the improvement of people's living standards, it is imperative to reduce the energy consumption of air-conditioning systems. Generally, air-conditioning systems adopt large temperature difference systems of cold water. By changing the operating parameters of cold water and cooling water, the energy consumption of water distribution pumps is reduced to achieve energy conservation.

When the inlet water temperature and temperature difference are different, the changes of various performance parameters of fan coil units also present different laws:

(1) For the same water supply temperature, with the increase of water supply temperature difference, the total thermal cooling capacity, sensible thermal cooling capacity, latent thermal cooling capacity and moisture evolution coefficient of fan coil units all decrease, while the heat-moisture ratio increases.  Moreover, sensible heat and cold change slowly, latent heat and cold change quickly, while total heat and cold change is between the two.

(2) As the chilled water supply temperature decreases, the effect of the temperature difference on the total thermal cooling capacity, sensible thermal cooling capacity, latent thermal cooling capacity and moisture evolution coefficient of the fan coil unit will decrease accordingly.


It can be seen that with the increase of water supply temperature difference, the cooling capacity of the fan coil unit decreases while the dehumidification capacity of the fan coil unit also decreases obviously, which easily leads to unsatisfied dehumidification requirements of air-conditioned rooms.

From the above analysis, it can be seen that in order to achieve the purpose of energy conservation in the operation of large temperature difference design, certain measures must be taken for fan coil units to make up for the adverse effects caused by large temperature difference.  

Related News
Read More >>
Water source rooftop chiller unit part in HAVC Water source rooftop chiller unit part in HAVC
Mar .22.2024
The fan coil unit is a common HVAC system terminal device. It can be used independently or in conjunction with other equipment to provide more efficient cooling and heating services. One such example is the water-source chiller.
The quietness and efficiency of Guqin series Horizontal Ultra-Thin Concealed fan coil units The quietness and efficiency of Guqin series Horizontal Ultra-Thin Concealed fan coil units
Mar .22.2024
The Guqin Series Vertical and Horizontal Ultra-Thin Concealed Fan Coil Unit is a HVAC terminal component product produced by Yesncer, named after the world’s intangible cultural heritage – the Guqin. Not only does it have an exquisite appearance, but its
Ultra-low temperature air source heat pump principle and core technology Ultra-low temperature air source heat pump principle and core technology
Dec .27.2023
The principle of ultra-low temperature heat pump system is as follows.
Fan Coil Unit Selection And Product Advantages Fan Coil Unit Selection And Product Advantages
Dec .07.2023
Fan Coil Unit Selection And Product Advantages